CSF dynamical parameters

NPH is the result of an imbalance in the CSF dynamical system, and thus it is important to measure the intracranial pressure and other parameters such as CSF absorption which affect the system. LIKVOR CELDA® SYSTEM allows for a thorough investigation to be made, where the pressure and flow dynamics of each patient is carefully examined.

Predictive parameter

CSF is produced within the brain, circulates around the brain and spinal cord, and is finally re-absorbed into venous blood. One predictive test, to try to determine whether a patient will benefit from shunt surgery or not, is the infusion test. With LIKVOR CELDA® SYSTEM an infusion test can be performed using a variety of methods, to estimate the rate of re-absorption of cerebrospinal fluid into the blood. If the absorption is malfunctioning, this indicates that the patient is likely to improve from shunt surgery.

Control of shunt function

After surgery, an infusion test performed with LIKVOR CELDA® SYSTEM is invaluable in determining whether or not an implanted shunt is functioning correctly. If a patient improves post surgically but later changes for the worse, it is most important to be able to determine if there is a problem with the shunt implant, or if the condition of the patient has deteriorated although the shunt is functioning correctly. In this way unnecessary reoperations can be avoided.

Infusion test with LIKVOR CELDA® SYSTEM

To perform an infusion test with LIKVOR CELDA® SYSTEM, two lumbar needles are placed into the spinal canal, below the spinal cord. The resting pressure of the patient is measured, and artificial CSF is infused in various patterns. Hereby the characteristic parameters of the system can be estimated, including important adherent statistical parameters.

The investigation takes approximately one hour, and during that time the patient is lying in the supine position on a specially designed bed in a relaxed way, not uncommonly sleeping through parts of the investigation. For estimating CSF absorption the constant pressure method is recommended, but several other methods are also implemented in LIKVOR CELDA® SYSTEM, including constant infusion and bolus algorithms, to allow for a diversity of investigations to be made.

LIKVOR CELDA® SYSTEM is a medical device that will simplify the mapping of CSF-dynamics in a safe and reproducible way.

Due to increased knowledge about the brain, brain disorders and their corresponding symp­toms, the need to measure CSF-dynamics has gradually become more and more important. Until today, CSF-dynamics has been investigated in many ways with mostly non-standardized, non-commercially available equipment. Therefore it has been difficult to gather, compare and sum­marize data obtained by research or from clinical investigations. LIKVOR CELDA® SYSTEM changes the situation for investigators work­ing either in the clinic, with research, or both. LIKVOR CELDA® SYSTEM offers automatic standardized protocols for multiple purposes in di­agnosis of patient CSF-dynamics before and after operation of shunt, in shunt-control, with con­stant flow or constant pressure measurements etc. With its flexibility and easy handling LIKVOR CELDA® SYSTEM sets a new standard for inves­tigations of CSF-dynamics.